Mobile furnace - Cost-effective on-site fire resistance test
Real-time filming from within the mobile furnace allows continuous observation of the tested structure. This can be used to support the analysis of the test. Even more importantly, for concrete test objects observation of the structure enables an instant “stop” of the test when concrete spalling begins. Therefore the damage to the structure can be kept to a minimum. In most cases, only the first few millimetres of the concrete surface need to be repaired. n The test surface of 1m2 can be large enough to obtain reliable test results, but small enough to prevent unnecessary damage to the structure. n Engineering tools and computer modelling can also be used when assessing the structure. n The MobiFiRe-ISO and MobiFiRe-RWS furnaces can be applied to all kinds of structural elements, such as ceilings, floors, roofs and walls. n Efectis can provide all the equipment necessary for on-site testing, including electricity supply and an elevation platform. n Operation is safe and complies with the necessary safety rules and regulations. n Fast and flexible setup and dismantling, which allows the fire test to be performed in only a few hours. n The MobiFiRe service is flexible. Testing according to your specific wishes is always possible.